To test these sensitivities in the model, Ray took the E802 data, and fed first only the kaon singles spectra and pairs data to freezer, and in a separate run, only the pion singles and pairs data. The results are shown below. The error bars indicate the sensitivity of the parameter to the data sets.
Nine independent source freezeout parameters for central Si-Au at 14.6 GeV/nucleon | ||
---|---|---|
Value and uncertainty at 99% confidence | ||
Property | from kaons | from pions |
n/n_0 | 0.26 +0.17 -0.12 | 0.01 +0.59 -0.01 |
T (MeV) | 101 +- 10 | 78 +- 20 |
v_t (c) | 0.62 +- 0.14 | 0.77 +- 0.14 |
v_l (c) | 0.89 +0.08 -0.20 | 0.920 +0.033 -0.056 |
v_s (c) | 0.847 +0.052 -0.076 | 0.880 +0.014 -0.015 |
R_t (fm) | 7.1 +- 2.5 | 9.5 +- 2.7 |
tau_f (fm/c) | 6.6 +- 3.8 | 11.1 +- 5.2 |
delta_tau (fm/c) | 2.9 +7.4 -2.9 | 8.4 +7.4 -4.6 |
lambda_pi | - | 0.75 +- 0.16 |