from
+
and optimize signal to background.
Resolve J/
from
' and optimize signal to background.
Resolve
(1S) from
(2S+3S) over all rapidity (including
central rapidity).
mass resolution
88 MeV/c2
mass resolution
100 MeV/c2
mass resolution
200 MeV/c2
Detector Characteristics and Performance:
100
m (rms per cathode plane)
0.5% of a radiation length.
10% of a radiation length each.
| Station | phi-cm/oct | strips/oct | Cathodes | r-cm/oct | wires/oct | Anodes |
| 1N | 104 | 96 | 4608 | 100 | 96 | 2304 |
| 2N | U:208 | 192 | 9216 | U:187 | 192 | 4608 |
| D:214 | D:194 | |||||
| 3N | 354 | 320 | 15360 | 320 | 320 | 7680 |
| Subtot N | Cathodes | 29184 | Anodes | 14592 | ||
| 1S | 104 | 96 | 768 | 100 | 96 | 2304 |
| 2S | U:178 | 160 | 7680 | U:161 | 160 | 3840 |
| D:186 | D:168 | |||||
| 3S | 268 | 256 | 12288 | 241 | 240 | 5760 |
| Subtot S | Cathodes | 24576 | Anodes | 11904 | ||
| Totals | Cathodes | 53760 | Anodes | 26496 |
| Station |
Whole Chassis |
Half Chassis |
# FEMs | # DCBs |
| 1N Cathodes | 20 | 0 | 40 | 10 |
| Anodes | 3 | 3 | 1 | |
| 2N Cathodes | 32 | 8 | 72 | 18 |
| Anodes | 3 | 3 | 1 | |
| 3N Cathodes | 56 | 8 | 120 | 30 |
| Anodes | 3 | 3 | 1 | |
| Subtot N-Arm | 108 | 25 | 241 | 61 |
| 1S Cathodes | 20 | 0 | 40 | 10 |
| Anodes | 3 | 3 | 1 | |
| 2S Cathodes | 32 | 0 | 64 | 16 |
| Anodes | 3 | 3 | 1 | |
| 3S Cathodes | 48 | 0 | 96 | 24 |
| Anodes | 3 | 3 | 1 | |
| Subtot S-Arm | 100 | 9 | 209 | 53 |
| Totals | 208 | 34 | 450 | 114 |