Notes about pad assemblies we tested
We accept grades A and B.
Overall summary of tested pad assemblies
fraction accepted = 3/6+-.20
the channel number counts 0 to 255
pad assembly | MCM | pad detector | date tested | accept or reject?
grade |
dead channels
[MCM] (detector) {new} |
notes |
P01 | 159 | 1776-16 | 16-Feb-00 | accept, A | (181, 223)
{233} |
Turn off the following channels: #0,1,50,71,181,254,255. There are bunches of odd behaving channels. these are 49, 67, 85, 117, 179, 205, 223, 233, 241, 245. sometimes these channels work and sometimes not. most of these channels happen to be identified bad(smaller slope by 1 or 2) channels at MCM QA |
P02 | 206 | 1895-14 | 16-Feb-00 | accept, B | [96~100]
(4, 22, 242, 251) {58, 85} |
Turn off the following channels: #0,1,4,22,242,251,254,255. |
P03 | 236 | 1896-24 | 16-Feb-00 | reject, C | (208)
{0~31} |
Turn off the following channels: #0,1,3,21,22,208,254,255. |
P04 | 168 | 1776-11 | 16-Feb-00 | accept, A | [49, 170, 173]
(143) |
Turn off the following channels: #0,1,143,254,255. 3, 40, 96, 129 have small signal 46 looks like working even though it was identified dead(0 slope) at MCM QA |
P05 | 128 | 1778-11 | 16-Feb-00 | reject, F | {all channels all blocks} | Turn off the following channels: #0,1,63,91,188,254,255. registance between +5VD_HM_AND_ADC and ground is about 300ohm always gives overflows(0x3FF) for all channels all blocks |
P06 | 215 | 1896-15 | 16-Feb-00 | reject, F | {all channels all blocks} | Turn off the following channels: #0,1,74,247,254,255. PECLA does not come up on pin#49 serial download fails no data comes out of MCM |
summary
We accept grades A and B.
fraction accepted = 3/6 = 0.5 +- .20
updated 16-Feb-2000
Sangsu Ryu
the channel number counts 0 to 255 - MCM convention
pad assembly | MCM | pad detector | date tested | accept or reject?
grade |
dead channels
[MCM] (detector) {new} |
notes |
P07 | 117 | P1460-10 | 07-Mar-00 | accept, A | [1]
(2,19,38,134,248)
{98} |
Turn off the following channels: 0,1,2,19,38,134,248,254,255. Channel #98 is dead. |
P08 | 221 | P1459-03 | 07-Mar-00 | accept, A | [171]
(46)
{50,171} |
Turn off the following channels: 0,1,46,254,255. Channel #50 is dead. Channel #171 overflows. |
P09 | 241 | P1460-01 | 07-Mar-00 | accept, A | []
(204,238)
{} |
Turn off the following channels: 0,1,204,238,254,255. All other channels look good. |
P10 | 264 | P1460-03 | 13-Mar-00 | accept, A | []
(126)
{204,238} |
Turn off the following channels: 0,1,126,254,255. Channel #204 and #238 give no response - dead. |
P11 | 272 | P1460-06 | 13-Mar-00 | accept, A | []
(29,42)
{149} |
Turn off the following channels: 0,1,29,42,254,255. Channel #149 gives weak response. |
P12 | 274 | P1715-05 | 24-Mar-00 | accept, A | []
(76,253)
{} |
Turn off the following channels: 0,1,76,253,254,255. All other channels are good. |
P13 | 124 | P1895-05 | 05-Apr-00 | accept, A | []
(10,75,76,110,127,141)
{} |
Turn off the following channels: 0,1,75,76,110,127,141,254,255. Channel #10 is dead. Generally this assembly gives noisy response, but it's probably due to the change of setup which took place on 4/4/00. |
P14 | 130 | P1895-07 | 05-Apr-00 | hold, A??? | []
(5,8,12,55,192,203)
{} |
Turn off the following channels: 0,1,5,8,12,55,192,203,254,255. All other channels are alive but noisy. Setup problem? To be retested. |
P15 | 217 | P1895-04 | 04-Apr-00 | accept, A | []
(19,35,43,60,61,139,147)
{-43} |
Turn off the following channels: 0,1,35,60,61,139,147,254,255. Channel #19 is dead. Channel #43 is alive. |
P16 | 244 | P1895-19 | 04-Apr-00 | accept, A | []
(66,74,141,147,148,186,188)
{32,100,-148} |
Turn off the following channels: 0,1,66,74,141,147,186,188,254,255. Channel #32 and #100 are dead. Channel #148 is alive. |
summary
We accept grades A and B.
fraction accepted = 12/15 = 0.8 +- .10
1 to be retested.
updated 08-Aug-2000
Toshiyuki Shiina