dimensions Envelope: 75cm long, 30cm radius
active region inner barrel: | z | < 32cm. r=5cm.
outer barrel: | z | < 32cm. r=7.5cm; Si removed on the top 2/3 of the barrel for |z| < 21 cm
pads: r = 5-12cm at z=+-35cm
acceptance full coverage in azimuthal angle.
pseudorapidity coverage: < 2.5 for the barrel,
1.8-2.5 for the pads.
channels inner barrel: 12 c-modules x 6 in phi x 256 strips/detector= 18432
outer barrel: ( 4x6 + 8x2 ) x 256 = 10240
pads: 8 detectors in phi x 12 columns x 20 in r = 6048
total: 35K channels
weight about 5.5 kg
thickness X0 = 0.61% for tracks traversing 1 silicon detector, and 0.96% for 2 silicon layers.