MVD Mounting
- MVD can find the beam location
- MVD located to magnet
- Simplifies Installation Fixture design
- Alignment done during installation of mounting system
- components - this procedure can be done months
- before the arrival of the MVD
- Eliminates alignment monitor (MVD is its own monitor)
- Spring loaded mounting points w/retraction pin (6 total)
- South bottom position acts as the reference location
- socket captures pivot pin in XYZ (10 lb/in spring)
- South top positions have vertical slots - XZ positoning
- (10 lb/in spring)
- North bottom position has a socket to capture the pivot pin
- (2 lb/in sping), XY positioning
- North top postions have vertical slots and weaker spring
- X positoning
- No tool installation - except when retracting the mounting points
- Allows for thermal expansion