This page contains a summary taken from Jehanne's notes from visual and electrical (look for shorts) tests of surface-mount components on the MCMs. I am unclear on the exact dates of some of the tests.

I try to give a brief description of the location of any surface-mount component with a problem noted by Jehanne. My description assumes you are looking at the top surface of the MCM with the 256 pin input connector on the left and the 50 pin output connector on the right.

The results summarized here are from the first round of inspections, done in early August 1999, on each MCM. Many or all of these problems have since been fixed. For details on the second round of inspections, after misc repairs at Pace, look here.

In the table below, I only listed problems which Jehanne's notes say "fix" next to. Other comments and notes from the original data sheets are omitted.


MCM date problem location
101 10-Aug-99 C122 shorted near TGV#2, top left
102 6-Aug-99 no problems --
105 6-Aug-99 no problems --
106 6-Aug-99 no problems --
107 early Aug C238, cracked epoxy near TGV#5, center left
107 early Aug C3, cracked epoxy near HM, center right
107 early Aug C49 missing near TGV#4, middle middle
109 early Aug C122 shorted near TGV#2, top left
109 early Aug C2 very little expoxy near HM, top right
111 10-Aug-99 no problems --
112 5-Aug-99 no problems --
113 early Aug C4006 shorted near TGV#2, top left
114 6-Aug-99 no problems --
116 6-Aug-99 no problems, except one row of caps (on TGVs) "looks like bad contact although survive pull test". Later judged OK. --
117 10-Aug-99 no problems --
118 5-Aug-99 epoxy splash near TGV3 and 4, middle left
119 10-Aug-99 no problems --
120 10-Aug-99 loose components, judged OK --


John Sullivan
updated 3-Sep-1999