Looking at the top of station1. The cables 1-4 go to the
first ROC board, the next 4 to the next ROC. At this end, cables
1 and 3 are shorter than cables 2 and 4 by 19 mm, and the distance from the
center of the HV connector to the extension cable end is 14.5 mm.
In this view: cable type ------------- 1 2B 3204 2 1B 3203 3 2A 3202 4 1A 3201 | |
Assume the bias cables follow the same path as the extension cables. Note that bias cable 2 follows the straight extension cable that is highlighted, so we can use it's length for part of the bias cable path. This is cable 111-PHX-02-3201.PDF, length 280.3 mm. On the HDI end, the distance from the center of the HV connector to the end of the cable is 14.5 mm. | |
On the ROC end, the distance from the cable end to the bias connectors
is AB minus the distance from the connector's center to the cable end, which is
193-8.7 = 184.3 mm.
280.3 cable length -14.4 Hirose to cable end at HDI 193.0 A-B on ROC board -8.7 half connector ------ 450.2 mmThis the connecter-center to connector-center length. |
station | ID | cable length | ROC | total | rounded up |
---|---|---|---|---|---|
station 1 | 3201 | 280.3 | 193 | 431 | 455 |
3202 | 297.4 | 450 | 455 | ||
3203 | 279.5 | 431 | 455 | ||
3204 | 299.9 | 455 | 455 | ||
station 2 | 3301 | 183.1 | 168 | 328 | 335 |
3302 | 170.8 | 316 | 335 | ||
3303 | 187.1 | 332 | 335 | ||
3304 | 174.8 | 320 | 335 | ||
station 3 | 3401 | 150.5 | 144 | 271 | 280 |
3402 | 139.9 | 261 | 280 | ||
3403 | 154.8 | 276 | 280 | ||
3404 | 144.2 | 265 | 280 | ||
station 4 | 3501 | 123.5 | 118 | 218 | 225 |
3502 | 123.2 | 218 | 225 | ||
3503 | 127.4 | 222 | 225 | ||
3504 | 123.6 | 218 | 225 |
6 April 2011: Constructing a cable in SolidWorks gives the following result: |
Bias cables received: inches mm station ------------------------------- 19.375 492 1 13.625 346 2 11.625 295 3 9.125 232 4 ---------------------------------------------