STARTING AND MONITORING A RUN, fn866:PROCEDURES.TXT - CNB - 7/31/96 PDP11/45: 1) VME must be started before the PDP - standard PDP commands are: STARt, STOP, PAUSe, CONTinue, SHOW STAT, DISP OED 1 (or 2), SHOW RUNS 2, DUMP RAW, DISP HIST xx, .... VME: 1) While the PDP is in the stopped state, type 'EnableTaping 1', wait for tape to load, then type 'StartRun xxx' where the run number xxx must agree with the NEXT RUN NUMBER displayed on the PDP. 2) After run is stopped on the PDP, type 'StopRun' + 'DisableTaping' FN789: 1) Login, type 'scan' to start scaler display FN866: 1) Login, type 'showstat' to display run status type 'swic' to display beam chamber type 'review' to graph previous values of any variables DISNEY: 1) Login, move cursor to Page, hit return; with Mouse, double click on 'Select', then 'Page', then 'E866' 2) The magnets SM0 (ME6AN), SM12 (ME7AN1), and SM3 (ME7AN2) must be turned on by Operations (x4532) but their currents can be adjusted by us by clicking to the right of the appropriate 'SET' value, erasing it by backspacing over it, and typeing in the new value with a return. The nominal settings for the 'SET' point are: SM0 (ME6AN): 0 or 2100, SM12 (ME7AN1): 2040 or 2800, SM3 (ME7AN2): 4200